Quick Detail
Feature
- Accuracy: Normal type: ±2.5%, high accuracy type: ±1.5%
- Measuring Medium: Liquid, gases or steam.
- Environment Temperature: -25℃~+100℃
- Medium Temperature: Standard Type: -20℃~+200℃
High Temperature Type: 300℃
Liner FEP Type: ≤90℃
- Medium Viscosity: DN15: ≤ 5mPa.s
≤ 30mPa.s
DN25:≤ 250mPa.s
DN50-150: ≤ 300mPa.s
- It has horizontal installation and vertical installation type rotameter.
- Flow Range Ratio: 10:1
- Power Supply: 24VDC, 3.6V lithium battery power
- Power voltage influence: ≤±0.1% F.S
- Load Influence: ≤±0.1%
- Max Working Pressure: DN15~DN50 is 4.0MPa, DN80~DN150 is 1.6MPa.
- Pipe Connection: Flange, Thread, Quick coupling
- Shell:Aluminum Alloy
- Protection Class: IP65, IP67
- Electrical Connection: M20×1.5 internal thread, M16×1.5 internal thread, 1/2’’NPT.
- Remote transfer converter: 4-20mA, HART protocol communication.
- Measure Pipe Material: Normal type is 1Cr18Ni9Ti,Anti-corrosive is PTFE.
- Explosion Proof: Mark: Exia II CT1~T6.
- Intrinsically safe explosion-proof: Mark: Exia II CT1~T6.
- Power terminal intrinsically safe parameters: Ui=28V Li=100mA Pi=0.7W
Ci=OnF Li=OnH
- Alarm terminal intrinsically safe parameters: Ui=28V Li=50mA Pi=0.1W
Ci=OnF Li=OnH